SS510 EchoRange+™ 200kHz Portable Survey, DT - 20m Cable
Part NumberSS510ERP-200-66
With Echo-envelope Developer option. Exclusive to OEMs. Available for purchase only through Airmar USA.
Airmar’s Smart™ sensors feature embedded microelectronics that process depth and temperature inside the sensor that can be instantly displayed on any device that accepts NMEA data. EchoRange technology transfers NMEA 0183 data in real time to a computer via the RS422 standard. In addition to the bi-directional NMEA 0183 interface, a secondary transmit only interface with a proprietary protocol using RS485 is available to OEMs. The user can obtain detailed echo envelope data which may be displayed as an analog waveform. The echo envelope is a 900-point time-series of the echo amplitude. By analyzing the shape of the echo envelope, information indicative of the seafloor type is revealed.
- Depth and temperature
- 200 kHz frequency
- Embedded transceivers
- Digital signal processing
- NMEA 0183* data-output
- User configurable, conserving bandwidth
- Control the depth range and the ping rate resolution, using the auto mode or manual setting capabilities
- Submersible down to 10M
- Mounting: Pole mount capable for portable installations
- Featuring Airmar's Smart™ Sensor technology
- Acoustic Window: UrethaneApplications: Bridge scour inspection systems, Portable hydrographic survey, Dredging, Autonomous Surface Drones, HydrodronesBeam Angle: 9°Cable Type: C316, 4 twisted shielded pairs with extreme grade urethane jacketCable-Length: Various lengths offered, Maximum 20 m (65'), 20 m (65.5')CE Certification: Marine standard IEC60945Comm Method: NMEA 0183/RS422Connector: Bare WireCurrent Draw: 150 mA @ 12 V for 200 kHzData Output: Smart® SensorDepth Accuracy: 99.46% at full range (see accuracy table for more info)Depth Display Resolution: 1 cm (.40")Echo Envelope Baud Rate: 921600Frequency Band: 200 kHzFull Auto Mode Data Output Rate: From 0.1 to 25 sec/intervalHousing Depth Rating: Submersible to 10 m (33')Manual Mode: Output rate equal to ping rateMaximum Depth Reading: 200 m (656'), limited in manual modeMinimum Depth Reading: 0.4 m (15.75"), limited in manual modeMounting: Pole mount capable for portable installationsNMEA 0183 Baud Rate: 4800 (Default)Operating Temp Range: -5C to +60CPower and Data Cable: ER SS510: C304, 4 twisted pairs with TPR jacketPower Supply Voltage: 9 to 40 VDC, RegulatedReverse Polarity Protection: YesSignal Type: NMEA-Smart®Stem Thread: 1/2"-14 NPSStorage Temperature Range: -30 to 70°C (-22 to 158°F)Temperature Resolution: 0.1CTemperature Sensor: 10k ohm +/-0.05C accuracyWeight: 1.3 kg (2.8 lb.)Functions: Depth, TemperatureDisplay Connector: 0
- Data Output Protocol
NMEA 0183* Standard Output Sentences $SDDPT Depth $SDDBT Depth Below Transducer
$SDMTW Water Temperature
NMEA 0183* Proprietary Commands/Responses
$PAMTC, OPTION, SOSTW
Speed of Sound Thru Water
$PAMTC, OPTION, DOFFSET
Depth Offset
$PAMTC, OPTION, TOFFSET
Temperature Offset
$PAMTC, EN
Enable/Disable Sentences
$PAMTC, BAUD
Change Baud Rate
$PAMTC, ERST
Reset User Eeprom
$PAMTC, FC
Query Format Code
$PAMTC, INFO
Query Device Information
$PAMTC, POST
Request Power on Self Test
$PAMTC, QV
Query Version Information
$PAMTC, QPS
Query Part and Serial Number
$PAMTC, RESET
Reset Processor
$PAMTC, OPTION, MANUAL
Manual Mode Commands
$PAMTC, OPTION, PING
Ping Control (On, Off, Once)
$PAMTC, OUTPUTMC Sentence Mode Control
$PAMTC, OPTION, PINGSPS Pings Per Second
$PAMTC, OPTION, PULSESPP Cycles Per Pulse
$PAMTC, OPTION, RANGE Depth Range Control
$PAMTC, OPTION, RANGEDEFAULT Default Depth Range Control
$PAMTC, OPTION, SFILTER Sample Filter Control
$PAMTC, OPTION, DFILTER Depth Filter Control
$PAMTC, EEC Echo Envelope Control
*NMEA 0183 is a serial data bus standard communications protocol that permits different types of electronic equipment to communicate. For more information visit www.nmea.org